7.4 Parameter Settings in Remote Net Additional Mode

Item
Set the "Number of Modules" for which the network parameters are to be
set.
Default value: Blank
Number of Modules
Setting range: Blank, 1 to 4 (boards)
For L02CPU, setting range: Blank, 1 to 2 (boards)
Modules for the parameter setting with the G(P).RLPASET instruction
should not be included in the setting for "Number of Modules".
Set the "Start I/O No." of the module.
Start I/O No.
Default value: Blank
Setting range: 0000 to 0FE0
The "Operation Setting" screen is displayed by clicking the Operation

Operation Setting

Setting button.
Set the station type.
Default value: Master Station
Setting range: Master Station
Type
7 - 21
This section explains the parameter settings using GX Works2.
The following shows the network parameter screen.
The following shows the setting items of the network parameter screen.
Master Station (Duplex Function)
Local Station
Standby Master Station
Description
7 PARAMETER SETTINGS
Standby
Master
Local
Master
Reference
station
station
station
Section
: Available,
: Not available
(To the next page)
7 - 21
――
――