Mitsubishi LJ61BT11 User Manual page 368

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

Address
Hex.
18
to 1F
H
H
20
(first module)
H
to
5F
(64th module)
H
60
to 7F
H
H
80
(Send buffer)
128(Send buffer)
H
81
(Receive buffer)
129(Receive buffer)
H
82
(Automatic update
130(Automatic update
H
buffer)
to
CB
(Send buffer)
203(Send buffer)
H
CC
(Receive buffer)
204(Receive buffer)
H
CD
(Automatic update
205(Automatic update
H
buffer)
CE
, CF
H
H
D0
to D3
H
H
1 Used in the remote net ver.2 mode or remote net additional mode.
2 When the setting is "8 Points + 8 Points (Reserved)", the station numbers are stored into both the 8-
point remote I/O station setting and 16-point remote I/O station setting.
App - 4
Dec.
24 to 31
(Use prohibited)
32 (first module)
to
Station information
95 (64th module)
96 to 127
(Use prohibited)
buffer)
Allocation of
communication
to
buffer and
automatic update
buffer
buffer)
206, 207
(Use prohibited)
8-point remote
208 to 211
I/O station setting
Item
Stores the setting status of the types of the connected slave
stations.
Default value: 0101
Storage area: Refer to the following
b15
to
b12
b11
Number of
Station type
occupied stations
0
: Ver. 1 compatible remote I/O station
H
1
: Ver. 1 compatible remote device station
H
2
: Ver. 1 compatible intelligent device station
H
5
: Ver. 2 compatible single remote device station
H
6
: Ver. 2 compatible single intelligent device station
H
8
: Ver. 2 compatible double remote device station
H
9
: Ver. 2 compatible double intelligent device station
H
B
: Ver. 2 compatible quadruple remote device station
H
C
: Ver. 2 compatible quadruple intelligent device station
H
E
: Ver. 2 compatible octuple remote device station
H
F
: Ver. 2 compatible octuple intelligent device station
H
Stores the buffer memory assignment status at transient
transmission to the local, intelligent device and standby master
stations.
Default value
Send buffer size: 40
Receive buffer size: 40
Automatic update buffer size: 80
Storage area
Communication buffer : 0
Automatic update buffer: 0
Stores the station numbers of the remote I/O stations set as 8
points in the remote I/O station points setting.
Default value: 0 (no setting)
Storage area: Bit corresponding to the station number turns on.
Description
(Ver.1compatible remote I/O station,
H
Occupies 1 station, Station number 1) to 0140
(Ver.1compatible remote I/O station, Occupies 1
station, Station number 64)
to
b8
b7
to
Station number
1
: Occupies 1 station
H
2
: Occupies 2 stations
H
3
: Occupies 3 stations
H
4
: Occupies 4 stations
H
(64) (word)
H
(64) (word)
H
(128) (word)
H
(0) (word) (no setting) or 40
H
(word) to 1000
Note that the total size of the
communication buffer is within
1000
(4096) (word).
H
(0) (word) (no setting) or 80
H
(128) (word) to 1000
Note that the total size of the
automatic update buffers is within
1000
(4096) (word).
H
APPENDIXES
H
b0
1 to 64
(01
to 40
)
H
H
(64)
H
(4096) (word)
H
H
(4096) (word)
H
1,
2
(To the next page)
App - 4