Parameter setting method
(before change)
Parameter setting with GX
Works2
Parameter setting with the
G(P).RLPASET instruction
1 Note that data link continues to be performed if the designation of operation at CPU down ((S1) + 5) of the
G(P).RLPASET instruction is set to "Continue."
9 - 45
(j)
In order to change the parameter setting method, turn the power supply to
the programmable controller system off and back on, or reset the
programmable controller CPU.
The following table shows how the programmable controller CPU operates
when changing the parameter setting method without turning the power
supply to the programmable controller system off and back on, or resetting
the programmable controller CPU.
Parameter setting method
(after change)
Parameter setting with the
G(P).RLPASET instruction
Parameter setting with GX
Works2
(k) When the programmable controller CPU is switched from RUN to STOP,
RY of the master station and outputs to the slave station are retained
9. DEDICATED INSTRUCTIONS AND PROGRAMMING
Error notification method
The G(P).RLPASET
instruction completes with
an error.
LINK.PARA.ERR occurs in
the programmable controller
CPU.
Continuity of data link
Data link continues.
*1
Data link stops.
.
9 - 45