G(P).Rlpaset - Mitsubishi LJ61BT11 User Manual

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

9.1.8 G(P).RLPASET

Internal device
(System, user)
Set data
Bit
(S1)
(S2)
(S3)
(S4)
(S5)
(D)
[Instruction
[Execution
symbol]
condition]
G.RLPASET
GP.RLPASET
1
Device
Start I/O number of the module
Un
(First 2 digits of I/O No. with three digits)
(S1)
Start number of the device in which control data is stared.
Start number of the device in which slave station setting data
2
(S2)
is stored.
Start number of the device in which reserved station
2
(S3)
specification data is stored.
Start number of the device in which error invalid station
2
(S4)
specification data is stored.
Start number of the device in which send, receive and
2
(S5)
automatic refresh buffer assignment data is stored.
Device that is turned ON for one scan upon completion of
(D)
reading.
(D)+1 also turns ON at an abnormal completion.
1 The file register of each of the local device and the program cannot be used as a device for setting data.
2 When the setting data for (S2) to (S5) are not to be set, specify a dummy device.
9 - 31
The G(P).RLPASET instruction sets network parameters to the master station and
starts the data link.
Link direct device
File
register
Word
Bit
Command
Command
Master station set data
Description
9. DEDICATED INSTRUCTIONS AND PROGRAMMING
Usable devices
Intelligent
J \
function
module
Word
device
U \G
Un
(S1)
G.RLPASET
Un
(S1)
GP.RLPASET
Constant
Index
register
Z
K, H
(S2)
(S3)
(S4)
(S5)
(S2)
(S3)
(S4)
(S5)
Setting range
0 to FE
H
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Other
S
(D)
(D)
Data type
Binary 16 bits
Device name
Bit
9 - 31