Mitsubishi LJ61BT11 User Manual page 369

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

Address
Hex.
D4
to D7
H
H
D8
to DB
H
H
DC
to DF
H
H
1 Used in the remote net ver.2 mode or remote net additional mode.
2 When the setting is "8 Points + 8 Points (Reserved)", the station numbers are stored into both the 8-
point remote I/O station setting and 16-point remote I/O station setting.
Master station
Remote input (RX)
Address
E0
RX F to RX 0
For station
H
number 1
E1
RX 1F to RX 10
H
E2
RX 2F to RX 20
For station
H
number 2
E3
RX 3F to RX 30
H
E4
RX 4F to RX 40
For station
H
number 3
E5
RX 5F to RX 50
H
E6
RX 6F to RX 60
For station
H
number 4
E7
RX 7F to RX 70
H
E8
RX 8F to RX 80
For station
H
number 5
E9
RX 9D to RX 90
H
to
RX7CF to RX7C0
15C
For station
H
number 63
15D
RX7DF to RX7D0
H
15E
RX7EF to RX7E0
For station
H
number 64
15F
RX7FF to RX7F0
H
App - 5
Dec.
16-point remote
212 to 215
I/O station setting
0 points reserved
216 to 219
station setting
220 to 223
(Use prohibited)
(2) Remote input (RX) and remote output (RY)
Used when the remote net ver.1 mode or remote net additional mode is selected.
(a) Master station
1) Master station
The input status from the remote I/O station, remote device station
(RX) and local station (RY) is stored.
Two words are used per station.
2) Local station
Data to be sent to the master station is stored in the remote output
(RY) of the address corresponding to the host station number.
The input status from the remote I/O station, remote device station
(RX) and other local station is stored.
Two words are used per station.
... The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RY9E and RY9F cannot be used.)
(Station number 1: occupies 1 station)
to
Item
Stores the station numbers of the remote I/O stations set as 16
points in the remote I/O station points setting.
Default value: 0 (no setting)
Storage area: Bit corresponding to the station number turns on.
Stores the station numbers of the reserved stations set to 0 points.
Default value: 0 (no setting)
Storage area: Bit corresponding to the station number turns on.
remote I/O station/remote device station/local station
Remote I/O station
X0F
to
X00
X1F
to
X10
Description
Local station
(Station number 2: occupies 4 stations)
Remote output (RY)
RY F to RY 0
160
RY 1F to RY 10
161
RY 2F to RY 20
162
RY 3F to RY 30
163
RY 4F to RY 40
164
RY 5F to RY 50
165
RY 6F to RY 60
166
RY 7F to RY 70
167
RY 8F to RY 80
168
RY 9D to RY 90
169
to
to
RY7CF to RY7C0
1DC
RY7DF to RY7D0
1DD
RY7EF to RY7E0
1DE
RY7FF to RY7F0
1DF
APPENDIXES
1,
2
1
Address
For station
H
number 1
H
For station
H
number 2
H
For station
H
number 3
H
For station
H
number 4
H
For station
H
number 5
H
For station
H
number 63
H
For station
H
number 64
H
App - 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-bt

Table of Contents