Creating A Program - Mitsubishi LJ61BT11 User Manual

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

12.3.4 Creating a program

Master station
Master station
programmable
Ver.1 compatible
controller CPU
buffer memory
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
Y100F to Y1000
RY00F to RY000
Y101F to Y1010
RY01F to RY010
Y102F to Y1020
RY02F to RY020
Y103F to Y1030
RY03F to RY030
Y104F to Y1040
RY04F to RY040
Y105F to Y1050
RY05F to RY050
Y106F to Y1060
RY06F to RY060
Y107D to Y1070
RY07F to RY070
Ver.2 compatible
buffer memory
X150F to X1T500
RX08F to RX080
X151F to X1510
RX09F to RX090
X152F to X1520
RX0AF to RX0A0
X153F to X1530
RX0BF to RX0B0
X154F to X1540
RX0CF to RX0C0
X155D to X1550
RX0DF to RX0D0
Y150F to Y1500
RY08F to RY080
Y151F to Y1510
RY09F to RY090
Y152F to Y1520
RY0AF to RY0A0
Y153F to Y1530
RY0BF to RY0B0
Y154F to Y1540
RY0CF to RY0C0
Y155D to Y1550
RY0DF to RY0D0
The last two bits cannot be used for communication between the master and local stations.
12 - 31
12 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS
This section shows the program to be used for communication between the master
and local stations. The following diagram shows the relationship between the devices
of the master station programmable controller CPU and the devices of the local station
programmable controller CPU.
The shaded areas indicate the devices that are actually used.
[Remote input (RX) and remote output (RY)]
Ver.1compatible local station
(station number 1: occupies 4 stations)
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
RY06F to RY060
RY07F to RY070
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
RX06F to RX060
RX07F to RX070
(station number 5: occupies 2 stations: double)
Local station
programmable
Ver.1 compatible
buffer memory
controller CPU
Y100F to Y1000
RY00F to RY000
Y101F to Y1010
RY01F to RY010
Y102F to Y1020
RY02F to RY020
Y103F to Y1030
RY03F to RY030
Y104F to Y1040
RY04F to RY040
Y105F to Y1050
RY05F to RY050
Y106F to Y1060
RY06F to RY060
Y107D to Y1070
RY07F to RY070
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
Ver.2 compatible
buffer memory
RY06F to RY060
RY07F to RY070
RY08F to RY080
RY09F to RY090
RY0AF to RY0A0
RY0BF to RY0B0
RX06F to RX060
RX07F to RX070
RX08F to RX080
RX09F to RX090
RX0AF to RX0A0
RX0BF to RX0B0
Ver.2compatible local station
Local station
programmable
controller CPU
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y105F to Y1050
Y106F to Y1060
Y107D to Y1070
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X105F to X1050
X106F to X1060
X107D to X1070
Y150F to Y1500
Y151F to Y1510
Y152F to Y1520
Y153F to Y1530
Y154F to Y1540
Y155D to Y1550
X150F to X1500
X151F to X1510
X152F to X1520
X153F to X1530
X154F to X1540
X155D to X1550
12 - 31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: