Mitsubishi LJ61BT11 User Manual page 396

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

Number
Name
SW0062
Module operating
(662
)
status
H
SW0064
No. of retries
(664
)
information
H
SW0065
No. of automatic
(665
)
return stations
H
SW0066
Delay timer
information
(666
)
H
SW0067
Parameter information
(667
)
H
SW0068
Host parameter status
(668
)
H
SW0069
Loading status
(669
)
H
SW006A
Switch setting status
(66A
)
H
SW006D
Max. link scan time
(66D
)
H
SW006E
Current link scan time Stores the current value of the link scan time (in 1 ms units).
(66E
)
H
SW006F
Min. link scan time
(66F
)
H
SW0070
Total number of
(670
)
stations
H
SW0071
Max. communication
(671
)
station number
H
SW0072
Number of connected
(672
)
modules
H
3: This register checks and stores the status only at link startup.
App - 32
Stores the operation setting status of the module.
b15
b12 b11b10 b9
b8 b7 b6 b5 b4 b3 b2 b1 b0
0
to
0
0
0
Indicates the retry count setting information when there is an error
response.
1 to 7 (times)
Indicates the setting information for the number of automatic return
stations during one link scan.
1 to 10 (stations)
Indicates the delay time setting information.
Stores the parameter information area to be used.
0
: CPU built-in parameters
H
3
: Dedicated instruction (parameter setting with the
H
G(P).RLPASET instruction and data link startup.)
D
: Default parameters (automatically starts CC-Link)
H
Stores the parameter setting status.
0
: Normal
Other than 0: Stores an error code (refer to Section 15.3).
Stores the duplicate station number status and parameter matching of
each station.
0
: Normal
3
Other than 0: Stores the error code (refer to Section 15.3). Details
are stored in SW0098 to SW009B and SW009C to
SW009F.
Stores the switch setting status.
0
: Normal
Other than 0: Stores an error code (refer to Section 15.3).
Stores the maximum value of the link scan time (in 1 ms units).
Stores the minimum value of the link scan time (in 1 ms units).
Stores the final station number set in the parameter.
1 to 64 (stations)
Stores the maximum station number (set number of the station
number setting) that is performing data link.
1 to 64 (stations)
Stores the number of modules that are performing data link.
Description
0
Station type
0: Master station/local station
1: Standby master station
(Valid only when b1 is 0)
Master station duplex function
0: Master station duplex function invalid
1: Master station duplex function valid
Input status from the data
link faulty station
0: Clear
1: Hold
Number of occupied stations
00: Occupies 1 station
10: Occupies 2 stations
11: Occupies 3 stations
01: Occupies 4 stations
Master station/local station
start by dedicated instruction
0: Start by CPU parameter
1: Start by dedicated instruction
Slave station refresh/compulsory
clear setting in case of programmable
controller CPU STOP
0: Refresh
1: Clears compulsorily
Expanded cyclic setting
00: Single
01: Double
10: Quadruple
11: Octuple
Block guarantee of cyclic data per station
0: Not set
1: Set
Availability
(
: Available,
: Not available)
Online
Master station
Local station
(To the next page)
APPENDIXES
Offline
App - 32