Slave Station Refresh/Compulsory Clear Setting In Case Of Programmable Controller Cpu Stop - Mitsubishi LJ61BT11 User Manual

Melsec l series cc-link system master/local module
Table of Contents

Advertisement

8.2.5 Slave station refresh/compulsory clear setting in case of programmable controller CPU
STOP
Master station
Remote input (RX)
Station number 1
Station number 2
Station number 3
Station number 4
Remote output (RY)
Station number 1
Station number 2
Station number 3
Station number 4
Remote register
(RWw)
Station number 1
Station number 2
Station number 3
Station number 4
Remote register
(RWr)
Station number 1
Station number 2
Station number 3
Station number 4
8 - 27
This function forcibly clears the output data (remote output RY) to slave stations when
the programmable controller CPU comes to STOP.
Remote output RY refresh device setting in the automatic refresh parameter dialog box
provides the following choices.
When "Y" is specified, the remote output RY is cleared regardless of the parameter
setting.
When specifying any device other than "Y" (e.g. M or L), make parameter setting to
specify whether to refresh or forcibly clear the remote output RY.
For the status of each station at error occurrence, refer to Section 8.2.6.
(1) Target output (send) data
The following shows the applicable buffer memory areas.
Remote I/O station
(station number 1)
Input
Output
The remote output RY is refreshed or compulsorily cleared according to the
setting when the programmable controller CPUs for the master and local stations
come to STOP.
The remote input RX, remote register RWw and remote register RWr are
refreshed regardless of the setting when the programmable controller CPUs for
the master and local stations come to STOP.
Remote device station
(station number 2)
(station number 3)
Remote output (RY)
Remote input (RX)
Remote input (RX)
Remote output (RY)
Remote register
(RWw)
Remote register
(RWr)
Area of refresh/compulsory clear setting target
Area refreshed independently of setting
Local station
Local station
(station number 4)
Remote output (RY)
Station number 1
Station number 1
Station number 2
Station number 2
Station number 3
Station number 3
Station number 4
Station number 4
Remote input (RX)
Station number 1
Station number 1
Station number 2
Station number 2
Station number 3
Station number 3
Station number 4
Station number 4
Remote register
Remote register
(RWr)
(RWr)
Station number 1
Station number 1
Station number 2
Station number 2
Station number 3
Station number 3
Station number 4
Station number 4
Remote register
Remote register
(RWw)
(RWw)
Station number 1
Station number 1
Station number 2
Station number 2
Station number 3
Station number 3
Station number 4
Station number 4
8 FUNCTIONS
8 - 27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-bt

Table of Contents