Number
Name
SB0060
Host mode
(5E6
, b0)
H
SB0061
Host type
(5E6
, b1)
H
SB0062
Host standby master
(5E6
, b2)
station setting status
H
Input data status of
SB0065
host data link faulty
(5E6
, b5)
H
station
SB0066
(5E6
, b6)
H
Number of host
occupied stations
SB0067
(5E6
, b7)
H
SB006A
Switch setting status
(5E6
, b10)
H
SB006D
Parameter setting
(5E6
, b13)
status
H
SB006E
Host station operation
(5E6
, b14)
status
H
Setting status of block
SB006F
guarantee of cyclic
(5E6
,b15)
H
data per station
SB0070
Master station
(5E7
, b0)
information
H
SB0071
Standby master
(5E7
, b1)
station information
H
SB0072
Scan mode setting
(5E7
, b2)
information
H
Operation
SB0073
specification when
(5E7
, b3)
H
CPU is down status
SB0074
Reserved station
(5E7
, b4)
specified status
H
SB0075
Error invalid station
(5E7
, b5)
specified status
H
App - 25
Description
Indicates the mode setting status of the host.
OFF: Online
ON : Other than online
Indicates the station type of the host.
OFF: Master station (station number 0)
ON : Local station (station numbers 1 to 64)
Indicates whether or not the standby master station setting exists for
the host.
OFF: No setting
ON : Setting exists
Indicates the input status setting from a data link faulty station of the
host.
OFF: Clear
ON : Retain
Indicates the setting status of host occupied stations.
Number of
occupied station
1 station
2 stations
3 stations
4 stations
Indicates the switch setting status.
OFF: Normal
ON : Setting error exists (the error code is stored in SW006A)
Indicates the parameter setting status.
OFF: Normal
ON : Setting error exists (the error code is stored in SW0068)
Indicates the data link communication status with other stations.
OFF: Being executed
ON : Not executed
Indicates the "Block Data Assurance per Station" setting status.
OFF: Not set
ON : Set
Indicates the data link status.
OFF: Data link control by the master station
ON : Data link control by the standby master station
Indicates whether or not a standby master station is present.
OFF: Not present
ON : Present
Indicates the scan mode setting information.
OFF: Asynchronous mode
ON : Synchronous mode
Indicates the operation specification status using a parameter when
the CPU is down.
OFF: Stop
ON : Continue
Indicates the reserved station specification status using a parameter.
OFF: No specification
ON : Specification exists (information is stored in SW0074 to
SW0077)
Indicates the error invalid station specification status using a
parameter.
OFF: No specification
ON : Specification exists (information is stored in SW0078 to
SW007B)
SB0066
SB0067
OFF
OFF
OFF
ON
ON
ON
ON
OFF
Availability
(
: Available,
: Not available)
Online
Master station
Local station
(To the next page)
APPENDIXES
Offline
App - 25