15.3.2 Error code list

Error code
Error details
(hexadecimal)
4000 to
(Errors detected by the
4FFF
programmable controller CPU)
7000 to
(Errors detected by serial
7FFF
communication module, etc)
Message transmission function
B10C
unsupported
Transient data can not be
B110
received.
Transient data receiving order
B111
error
B112
Transient data length error
B113
Transient data ID error
B115
Link error
B116
Packet error
Forced termination of the
B120
remote device station initialize
procedure registration function
Error at a station on which the
remote device station initialize
B124
procedure registration function
was executed
Parameter not set error of the
B125
remote device station initialize
procedure registration function
Corresponding station error
B201
during sending
B205
Transient target station error
Processing request error during
B301
link stop
Specified station number
B302
setting error
15 - 23
The following shows the error codes list.
When the standby master station is operating as the master station, the detectability is
identical to that of the master station.
When the standby master is operating as a local station, the detectability is identical to
that of the local station.
Cause of error occurrence (details)
———
———
The message transmission function was
executed for the remote device station
that does not support the function.
A line error has occurred.
A line error has occurred.
A line error has occurred.
A line error has occurred or an
instantaneous power failure has occurred
at the send station.
A line error has occurred.
A line error has occurred.
In the remote device station initialize
procedure registration function, the
specification of the remote device station
initialize procedure registration was turned
off before all procedures were completed.
The specification of the remote device
station initialize procedure registration
function was turned on at a station other
than the master station.
The specification of the remote device
station initialize procedure registration
function was turned on without setting the
remote device station initialize procedure
registration.
Bits corresponding to other than the head
station number were turned ON in the
Specification of remote device station to
be initialized (SW0014 to SW0017) to
instruct remote device station initialization
procedure registration.
A data link error occurred at the
corresponding station during transient
transmission.
A transient request was issued to other
than the intelligent device station.
Loop test request was issued while the
link was stopped.
The specified station number exceeded
the highest communication station
number during temporary error invalid
request/temporary error invalid cancel
request.
Corrective action
Take corrective actions, referring to
the troubleshooting section of the
MELSEC-L CPU Module User's
Manual (Hardware Design,
Maintenance and Inspection).
Take corrective actions, referring to
the troubleshooting section of the
MELSEC-L Serial Communication
Module User's Manual.
Check the station No. of the target
station.
Or, check if the target station
supports the message transmission
function.
Check the line.
Check the line.
Check the line.
Check the line, or check the supply
power and power supply module of
the send station.
Check the line.
Check the line.
Do not turn the specification of the
remote device station initialize
procedure registration off until all
procedures are completed.
Turn on the remote device station
initialization procedure registration
instruction on the master station
(station No.0).
Turn on the specification of the remote
device station initialize procedure
registration function after setting the
remote device station initialize
procedure registration.
Turn ON only the bit corresponding to
the head station number in the
Specification of remote device station
to be initialized (SW0014 to
SW0017).
Check the communication status of
other stations, whether or not a
temporary error invalid station is
specified, or if the corresponding
station is stopped.
Check the target station.
Perform a loop test while the link is
being established
Specify a station number that is no
greater than the highest
communication station number.
15 TROUBLESHOOTING
Detectability
Master station
Local station