Configuring Poe On Ex6200 Switches; Table 61: Poe Edit Settings; Table 62: System Settings - Juniper EX Series User Manual

J-web application package
Hide thumbs Also See for EX Series:
Table of Contents

Advertisement

J-Web Application Package User Guide for EX Series Switches, Release 14.1X53-A1

Table 61: PoE Edit Settings

Field
Description
Enable PoE
Specifies that PoE is enabled on the interface.
Priority
Lists the power priority (low or high) configured on
the interface enabled for PoE.
Maximum Power
Specifies the maximum PoE wattage available to
provision the active PoE interface on the switch.

Table 62: System Settings

Field
Description
PoE
Specifies the power management mode. The options are:
Management
and
class
NOTE:
When the power management mode is set to
maximum power value is overridden by the maximum power value
of the class of the powered device that is connected to the switch
on the PoE port. When the power management mode is set to
, you can specify the maximum power for each PoE interface.
static
Guard Band
Specifies the amount of power reserved for power spikes from
(watts)
the PoE power budget of the switch.

Configuring PoE on EX6200 Switches

120
NOTE:
If you are configuring a Virtual Chassis, the PoE configuring option
is displayed if any member of the Virtual Chassis supports PoE, even if the
Virtual Chassis master does not support PoE.
NOTE:
After you make changes to the configuration on this page, you
must commit the changes for them to take effect. To commit all changes
to the active configuration, select
the Commit Options to Commit Configuration Changes for details about
all commit options.
Select one of the following options:
2.
—Changes PoE settings for the selected port as described in
Edit
—Modifies general PoE settings as described in
System Settings
.
To configure PoE:
>
Commit Options
Your Action
Select this option to enable PoE or PoE+ on the
interface.
Set the priority as
or
High
Select a value in watts. If no value is specified, the
default is 15.4 for PoE interfaces and 30.0 for
PoE+ interfaces.
Your Action
By default, the power management
static
mode is
class
. Select
the power management mode.
, the
class
Enter a value to set the guard band
value in watts. The default value is 0.
Copyright © 2017, Juniper Networks, Inc.
. See Using
Commit
Table 61 on page
120.
Table 62 on page
120.
.
Low
static
to change

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents