Connecting Earth Ground to an EX-series Switch
To meet safety and electromagnetic interference (EMI) requirements and to ensure
proper operation, EX-series switches must be adequately grounded before they are
connected to power.
For installations that require a separate grounding conductor to the chassis, use the
protective earthing terminal on the EX-series switch chassis to connect to the earth
ground. The protective earthing terminal is located on the left side of the chassis in
an EX 4200 switch when you look at it from the front. The protective earthing terminal
is located on the rear of the chassis in an EX 3200 switch.
An AC-powered EX-series switch chassis gets additional grounding when you plug
the power supply in the switch into a grounded AC power outlet by using an AC
power cord appropriate for your geographical location (see AC Power, Connection,
and Power Cord Specifications).
Ensure you have the following tools and parts available to connect an EX-series switch
to earth ground:
Electrostatic discharge (ESD) grounding strap
Grounding cable. The grounding cable must be minimum 6 AWG (13.3 mm²),
minimum 90°C wire, or as permitted by the local code.
Washers and 10-32x.25 in. screws to secure the grounding lug to the protective
earthing terminal
Phillips (+) screwdriver, number 2
Ensure you understand how to prevent ESD damage (see Preventing Electrostatic
Discharge Damage).
Ensure that a licensed electrician has attached an appropriate grounding lug to the
grounding cable.
CAUTION: Using a grounding cable with an incorrectly attached lug can damage the
switch.
To connect an EX-series switch chassis to earth ground (see Figure 1 on page 2):
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and
1.
connect the strap to the ESD point on the chassis.
Connect one end of the grounding cable to a proper earth ground, such as the
2.
rack in which the switch is installed.
With a Phillips (+) screwdriver, number 2, remove the screws and washers from
3.
the protective earthing terminal on the chassis.
Place the grounding lug attached to the grounding cable over the protective
4.
earthing terminal, as shown in Figure 1 on page 2.
Secure the grounding lug to the protective earthing terminal, first with the
5.
washers, then with 10-32x.25 in. screws.
Connecting Earth Ground to an EX-series Switch
1

Advertisement

loading

Summary of Contents for Juniper EX Series

  • Page 1 Connecting Earth Ground to an EX-series Switch To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, EX-series switches must be adequately grounded before they are connected to power. For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the EX-series switch chassis to connect to the earth ground.