Recirculation Control Motor Circuit Troubleshooting (cont'd)
10. Turn the ignition switch OFF.
11. Check for continuity between the following
terminals of heater control panel connector A (14P)
and the recirculation control motor 5P connector.
14P:
5P:
NO.5
No.1
No.6
No.2
HEATER CONTROL PANEL CONNECTOR A (14P)
Wire side of female terminals
.Q
GRN/YEL
RECIRCULATION CONTROL MOTOR 5P CONNECTOR
Wire side of female terminals
Is there continuity?
YES-Check for loose wires or poor connections at
heater control panel connector A (14P) and at the
recirculation control motor 5P connector. If the
connections are good, substitute a known-good
heater control panel, and recheck. If the symptom/
indication goes away, replace the original heater
control panel..
NO-Repair any open in the wire(s) between the
heater control panel and the recirculation control
motor .•