Wiring Automatic Single Stroke/External Trip

DANGER
!
PRESS STARTS UNEXPECTEDLY
• Ensure that light curtains and other safeguards are properly installed and operating to
protect operators when using automatic single stroke. Since the external trigger starts the
stroke, a stroke can occur unexpectedly.
• Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
Automatic Single Stroke/External Trip allows the operator to automate a manual press using
a feeding device or robot. See Figure 3 at the end of the manual to wire the External Trip
Actuator. Also see Table A at the end of the manual. Though a SPDT contact is shown in
this figure, you can also use solid state switches (proximity, for example), or outputs from a
programmable logic controller (PLC). To make sure that the contacts are clean and reliable,
the switch or relay should be new and unused.
To use Automatic Single Stroke, you must set Press Option Switch 5 to the appropriate
setting (see page 245). To run in this mode, see "Operating the Press in Automatic Single
Stroke Mode," page 373.

Wiring Continuous on Demand

DANGER
!
PRESS STARTS UNEXPECTEDLY
• Ensure that light curtains and other safeguards are properly installed and operating to
protect operators when using Continuous on Demand mode, in which a stroke can occur
unexpectedly.
• Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
For information on using this mode, contact Wintriss Tech Support. To use Continuous on
Demand, you must set Press Option Switch 5 to the appropriate setting (see page 245). See
also "Operating the Press in Continuous on Demand," page 377.