1126800
g.
After the board is properly seated, screw the four corners down again (from step 3c).
h.
Reconnect the connections from the sensor interface, remote connection box or cam
output assembly to the new board(s). Note that if you went from 8 to 16, you will
have to connect cables to the board. These are the terminal blocks to which you
will connect the cables:
ProCamPAC 8: Cam channels 1-8 to TB401
ProCamPAC 16: Cam channels 1-8 to TB451; 9-16 to TB452
DiProPAC 8: Sensors 1-8 to TB501
DiPro 16: Sensors 1-8 to TB551; 9-16 to TB552
i.
Verify that you have properly installed the boards. Go to "Verify Proper
Installation of ProCamPAC and/or DiProPAC Options," page 100. You need to
complete this before you use SmartPAC 2.
4.
If installing a new board (or boards): Complete these steps for each board you are
adding. Refer to Figure 2 - 42 for the location of the board to be installed.
a.
Verify that you are still "grounded," and then get the new board.
b.
Plug the board in. The connectors on the underside of the board are keyed, so that
they can only be plugged in one way. These connectors will connect correctly with
the mating pins on the main SmartPAC 2 processor board.
c.
After the board is properly seated, use the four screws that came with the kit to
secure the board.
d.
Connect the cable(s) to the new board(s). Note that if you are going from an 8 to 16
system, you will have to connect two cables to the board.
If you are upgrading ProCamPAC, the connector or connectors in question go to the
ProCam outputs assembly. If DiProPAC, the connector or connectors go to DiPro
Sensor Interface or DiPro RCB. If you need to connect 9-16 of the cams or
sensors, go back to the previous sections and complete the wiring.
These are the terminal blocks to which you will connect the ribbon cables:
ProCamPAC 8: Cam channels 1-8 to TB401
ProCamPAC 16: Cam channels 1-8 to TB451; 9-16 to TB452
DiProPAC 8: Sensors 1-8 to TB501
DiPro 16: Sensors 1-8 to TB551; 9-16 to TB552
e.
Verify that you have properly installed the boards. Go to "Verify Proper Installation
of ProCamPAC and/or DiProPAC Options," page 100. You need to complete this
step before you use SmartPAC 2.
4. Refer to the following instructions to wire the option you just installed:
• For ProCamPAC, see "Connecting Programmable Cam Channels," next section.
• For DiProPAC, refer to "Connecting DiPro Sensor Interface to SmartPAC 2," page
90, or "Installing the DiPro Remote Connection Box," page 92.
Page 82
SmartPAC 2 with WPC Integration
Chapter 2
Installing SmartPAC 2 and WPC

Hide quick links:

Advertisement

Table of Contents
loading