SmartPAC 2 with WPC Integration
Sensor on/off box does not appear to match the arc on the circle diagram, press the F4
function key, which changes the on/off reference point to 180° instead. This allows
SmartPAC 2 to correctly display the timing for a sensor that is actuated through the top of the
stroke.
NOTICE
When you press F5 you will see dashes ( — — ) next to "ON" and "OFF" in the sensor box
just before the information updates. Press F5 again to toggle back to normal actuation
mode.
NOTICE
Pressing F5 will not properly update sensor actuations when you are using a mechanical
sensor that vibrates constantly during the stroke. In cases like this, it is better to use an
electronic sensor which is not prone to constant contact bounce.
For HELP press the HELP key located at the center of the cursor (arrow) keys.

View Sensor Summary

(RUN – DIE PROTECTION – Select Sensor – F6 -VIEW SENSOR SUMMARY)
The Sensor Summary (next figure) is a list of the sensors names, giving for each the type of
sensor it is, its stop type and the ready window timing.
To see the Sensor Summary, go to the Die Protection menu screen (Figure 6 - 10), and press
F6-"View Sensor Summary." The following display appears, showing the sensor numbers,
names, type, stop type and on/off characteristics. "ES" stands for emergency stop, "TS" for
top stop, and "SS" for Smart Stop.
To exit from this display and go back to the Die Protection menu, press RESET.
SmartPAC 2 Run Mode
Figure 6 - 12. Sensor Summary Screen