Light Curtain Faults - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
Problem:
This error applies to cross-checked user input pair 8 & 9. It occurs if one
or both of the inputs are open.
Remedy:
Check the auxiliary equipment that signaled the stop. Correct the
problem. Reset SmartPAC. If the error does not go away, contact
Wintriss Tech Support for assistance.
Problem:
This error applies to cross-checked user input pair 10 & 11. It occurs if
one or both of the inputs are open.
Remedy:
Check the auxiliary equipment that signaled the stop. Correct the
problem. Reset SmartPAC. If the error does not go away, contact
Wintriss Tech Support for assistance.

Light Curtain faults

Problem:
These errors indicate that the light curtain(s) failed the internal light
curtain test conducted by WPC. There may be a problem with the wiring
of either the first or second light curtain connected to WPC (#60 applies to
the first, #61 applies to the second). This error can also be generated by
the second processor.
Remedy:Check that your light curtain wiring is correct. Refer to Chapter 2 either in this
manual in the light curtain user manual. If you need more assistance,
contact Wintriss Tech Support.
Page 402
50
58
60 or 61
Chapter 7
SmartPAC 2 with WPC Integration
SmartPAC 2 Fault Messages