Setting The Acts Angle (Optional) - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
USE THE CURSOR KEYS TO CHOOSE THE VALUE
YOU WANT TO CHANGE.
PRESS THE ENTER KEY TO CHANGE THE VALUE.
PRESS THE RESET KEY WHEN DONE.
3.
Use the number keys to set the value, and then press ENTER to confirm the value.
4.
Now select "Flywheel Timer."
5.
Use the number keys to set the value, and then press ENTER.
6.
Press RESET twice to return to the Main Initialization menu.

Setting the ACTS Angle (Optional)

See "Switch 4 – Auto Compensated Top Stop ("ACTS") Enabled (Optional)," page 244 for
information about Auto Compensated Top Stop ("ACTS"), a firmware option available for
WPC.
In most variable speed applications, the ACTS angle should be set at 0° (the default value).
However, there are exceptions. In top knock-out applications, the angle might be set after 0°,
while in some high-speed applications, the angle setting might be set before 0°. SmartPAC
will only allow you to enter a value for ACTS angle that is between 330° and 30°. Set ACTS
angle in the Press Control Parameter menu, Figure 4 - 25. For technical assistance, contact
the factory.
Page 240
PRESS CONTROL PARAMETER MENU
TOP STOP DEFLT
CARRYUP ANGLE
MICRO TIME
MICRO ANGLE
MAIN AIR LIMIT
CNTR BAL +/-
STOP LIMIT
START LIMIT
SHUT DOWN LIMIT
FLYWHEEL TIMER
ACTS ANGLE
INITIALIZE PARAMETERS
Figure 4 - 32. "Press Parameters" screen
Chapter 4
SmartPAC 2 with WPC Integration
=
220 DEG
=
149 DEG
=
100 MSEC
=
185 DEG
=
0 PSI
=
0 PSI
=
250
250 MSEC
=
199 MSEC
=
5 MIN
=
6 SEC
=
0 DEG
SmartPAC 2 Initialization Mode