Table 4 - 11. Switch 8 Settings For Top Stop With F And H Errors - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
Switch 8 – Top Stop Mode for F and H Errors and Auxiliary 1 Response to
Interrupted Stroke
NOTICE
After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
Switch 8 controls two different functions:
• Top Stop mode for F and H errors
• How Auxiliary Output 1 responds to an Interrupted Stroke condition (see below)
See the following two sections for descriptions of how to use Switch 8 to control these
functions.
Switch 8: Selecting Top Stop Mode for F and H Errors
You can use option switch 8 inside the unit to select whether the unit top stops the press
immediately if the error occurs after a crank angle of 210° .
Set Switch 8 in the Press Control Option Switches screen, Figure 4 - 33, page 241, according to
the following table.

Table 4 - 11. Switch 8 Settings for Top Stop with F and H Errors

Option Switch 8 Setting
OPEN
CLOSED
Switch 8: Selecting Auxiliary Output 1 Response to Interrupted Stroke
DANGER
!
NON-SAFETY OUTPUTS USED FOR SAFETY FUNCTIONS
Use auxiliary outputs 1, 2 and 3 for non-safety functions only. They cannot protect
personnel from a moving hazard. You can use them for convenience in automation.
Failure to comply with these instructions will result in death or serious injury.
The setting of this switch affects how Auxiliary output 1 responds to an Interrupted Stroke
condition as indicated below. See also "Wiring Auxiliary 1 Output (Optional)," page 64.
Page 248
Top Stop Behavior for F and H Errors
If the error occurs after 210 ° , the control allows the press to
complete another stroke before it top stops.
If the error occurs before 210 ° , the control top stops the press
on the same stroke.
The control top stops the press on the current stroke, even if
the error occurs after 210 °