Press Control; Adjusting Top Stop Angle, Press Speed Limits, Counterbalance Setpoint, Main System Air Limit.353 - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration

PRESS CONTROL

(RUN – PRESS CONTROL)
NOTICE
Find instructions for running the press at the end of this chapter, starting on page 364.
After you have programmed and loaded a tool number in SmartPAC's Programming mode,
you can make minor adjustments to certain WPC parameters in Run mode. The parameters
that you can adjust — Top Stop Angle, Maximum press speed, Minimum press speed,
Counterbalance setpoint — are discussed earlier in this chapter in the section "Making WPC
Settings in SmartPAC's Programming mode." To set the Counterbalance tolerance and the
Main system air limit, go to "Setting Main Air and Counterbalance Limits" in Chapter 4.
NOTICE
If you use the RamPAC option to control Counterbalance pressure, follow the instructions in
the RamPAC manual.
Adjusting Top Stop Angle, Press Speed Limits, Counterbalance
Setpoint, Main System Air Limit
1.
Select "Press Control" from the Run menu. This display shows the screen.
Figure 6 - 20. "Press Control" Display in Run Mode
2.
If you want to adjust "Top Stop Angle," press ENTER to let SmartPAC 2 know that you
want to change the value.
SmartPAC 2 Run Mode
Chapter 6
1126800
F1
F2
F3
F4
F5
F6
F7
F8
page 353

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents