Setting Parts/Stroke Or Strokes/Part - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
or about 10 seconds. See "Entering a number" in Chapter 3 if you need assistance.
Then press ENTER to accept the change.
NOTICE
When you select "toggle" or "pulse," the channel affected appears with the batch counter on
the top counter display (Figure 5 - 13).
Setting Counter Increment Angle
SmartPAC 2 also provides the ability to set counter increment angles for strokes, good parts,
and batch counters. The factory setting is 270°, which is satisfactory for counting parts,
means that the counters are incremented when the press passes 270°. However, if the batch
counter outputs are being used to control automation, the increment angles for these counters
should be set to the angle where you want the automation to activate.
1.
Move the cursor over and down to the "increment mode" column at the bottom of the
screen. You will be setting "stroke, good parts, batch 1." Press ENTER, then use the
number keys to make your selection. Press enter when done.
2.
Next, move the cursor down to the next one (batch 2), and repeat step 1.
3.
Repeat the above steps for batch 3.
Setting Counter Increment Mode
A third selection in "count mode" is the ability to set counter increment mode. Here you
determine whether the batch counter increments with the good parts counter or the strokes
counter. If you want the batch to count ALL strokes, then select "stroke." However, if you
want the batch to count the press strokes unless a die protection or other fault occurred, then
select "good parts." Follow these steps:
1.
Move the cursor to the third column "increment mode." You will be setting batch 1.
Press ENTER to toggle the selection between "stroke" and "good parts."
2.
Next, move the cursor down to the next one (batch 2), and repeat step 1.
3.
Move the cursor down to the last one (batch 3), and again repeat step 1. When you are
done, press RESET to return to the Main Programming menu.

Setting Parts/Stroke or Strokes/Part

You can set the number of parts produced per stroke or the number of strokes per part to
make the parts count reflect the actual number of parts made.
1.
From the Counter Mode Selections screen, press F1 (ADV. MODES). The screen
appears similar to the following figure.
page 290
SmartPAC 2 with WPC Integration
Chapter 5
SmartPAC 2 Program Mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents