1126800
Switch 6 – Dual Light Curtain Enabled
NOTICE
After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
Set this switch to CLOSED if you have two light curtains connected to WPC. Refer to
Figures 3 or 12 (for Herion valve) or Figure 5 (for Ross) to properly wire the dual light
curtains (end of this manual).
Set Switch 6 in the Press Control Option Switches screen, Figure 4 - 33, page 241.
Table 4 - 9. Switch 6 Setting for Single or Dual Light Curtains
Option Switch 6 Setting
OPEN
CLOSED
Page 246
Light Curtain Configuration
Single light curtain – normal operation
Dual light curtains enabled
Chapter 4
SmartPAC 2 with WPC Integration
SmartPAC 2 Initialization Mode