Enabling Or Disabling Setup Mode - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800

Enabling or Disabling Setup Mode

(INITIALIZATION - SENSOR ENABLE MODE)
NOTICE
If your SmartPAC 2 is not integrated with a WPC, your inch-selector switch must be wired to
the setup mode input, terminal #252 on TB107.
If you enable Setup mode, the green sensors are disabled in the condition you choose:
• In Inch mode
or
• In Inch mode and in Interrupted-stroke mode. (Available only with WPC integration)
For more information, see the Initialization chapter in your user manual.
1. To enable or disable Setup mode, in the Main Initialization menu, select SENSOR
ENABLE MODE.
USE THE CURSOR
KEYS TO CHOOSE
MENU ITEMS. PRESS
THE ENTER KEY TO
SELECT. SWITCH TO
RUN WHEN DONE.
A screen similar to the following appears.
SENSOR ENABLE MODE =
SETUP MODE
USE THE CURSOR KEYS TO SELECT THE MODE
YOU WANT TO CHANGE. PRESS THE ENTER KEY
TO CHANGE IT. PRESS THE RESET KEY WHEN
YOU ARE DONE.
Page 220
MAIN INITIALIZATION MENU
RESOLVER ZERO
POSITION SENSOR
INSTALLED OPTIONS
SELECT CAM NAMES
AUTO ADVANCE
CUSTOM SENSOR NAMES
SENSOR ENABLE MODE
SENSOR ENABLE MODE
PROCESS MONITOR
TOOL INFORMATION
RAMPAC INIT
PRESS CONTROL
SECURITY ACCESS
Figure 4 - 15. Main Initialization Menu
DIE PROTECTION MODE SELECTION MENU
=
Figure 4 - 16. Setup Mode Status
Chapter 4
SmartPAC 2 with WPC Integration
AUTO BY TOOL
DISABLED
DISABLED
SmartPAC 2 Initialization Mode