SmartPAC 2 with WPC Integration
Operating the Press in Automatic Single Stroke
Mode
DANGER
!
IMPROPER SAFEGUARDING
Ensure that the machine guarding system is installed and maintained according to OSHA
standard 1910.217, ANSI B11.1, ANSI B11.19 and any other regulations and standards that
apply. Ensure that guarding is properly installed to prevent access to the machine over,
under or around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
PRESS STARTING UNEXPECTEDLY
Ensure that light curtains and other safeguards are properly installed and operating to
protect operators when using automatic single stroke. Since the external trigger starts the
stroke, a stroke can occur unexpectedly.
Failure to comply with these instructions will result in death or serious injury.
The Automatic Single Stroke function allows an external event to automatically start a single
stroke within thirty seconds. Generally, material feed is used as the signaling event.
However, other events such as part ejection or positive part transfer, can be used.
There are three requirements for Automatic Single Stroke.
• you must have an Automatic Single Stroke switch installed. See Figure 6 at the end
of this manual
• you must have a trigger mechanism
• you must install proper guarding equipment to protect personnel, such as Shadow VI
light curtain and fixed guards.
As a triggering mechanism you can use a single pole double throw (SPDT) contact (switch or
relay) or two solid state switches (NPN, open collector).
To set prior act timing for automatic single stroke, see the next section
If you want to use Automatic Single Stroke, contact Wintriss Tech Support.
SmartPAC 2 Run Mode
Chapter 6
1126800
page 373