Green Quick Check
A sensor input set to "green quick check" is almost the same as the "green" setting. The
sensor must turn on at least momentarily within the ready signal. However, a green quick
check sensor cannot stay on or turn on outside the ready signal. The sensor must turn on,
then turn off within the ready signal. Otherwise, SmartPAC 2 sends the stop signal to the
press.
KEY
OK
TDC
= Ready
Signal
= Sensor
ON
BDC
Sensor goes ON
Green
only inside ready
Quick Check
Sensor
signal.
Figure 1 - 4. How SmartPAC 2 Interprets Signals From a Sensor Set to
Introduction to SmartPAC 2
not allowed
(press stops)
TDC
BDC
Sensor never goes
Sensor is ON outside ready signal.
ON.
Stop signal sent at
Stop signal sent when sensor is ON outside ready
end of ready signal.
signal.
"Green Quick Check"
Chapter 1
not allowed
(press stops)
TDC
TDC
BDC
BDC
1126800
TDC
BDC