7. Change to INCH mode and bring the ram to top dead center.
8. Change to SINGLE STROKE mode.
9. Momentarily press and release the RUN/INCH buttons. Observe the ram's behavior. It
should start moving when you press the buttons, then stop immediately when you release
them.
• If the ram moves, then stops, and the INTERRUPTED STROKE message flashes on
the display, continue on to step 14.
• If the ram does not move, or if it moves but does not stop immediately when you
release the buttons, or if the INTERRUPTED STROKE message does not flash on the
display, check the wiring and run the test from step 11 again. If the ram still does not
move or moves but does not stop immediately, or if the ram stops but the
INTERRUPTED STROKE message does not come on, contact Wintriss Tech
Support.
10. The press will now be in the TWO HAND MAINTAINED SINGLE STROKE mode.
Complete the stroke by pressing and holding the RUN/INCH buttons.
Go to the next applicable test.