Parameters
<value 0-61440> - Enter the bridge priority value, which must be divisible by 4096. The default
value is 32768.
instance_id - Specifies the identifier value, which is used to distinguish different STP instances.
<value 0-64> - Enter the identifier value, which is used to distinguish different STP instances.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure the STP instance ID:
DGS-3620-28PC:admin#config stp priority 61440 instance_id 0
Command: config stp priority 61440 instance_id 0
Success.
DGS-3620-28PC:admin#

100-13 config stp

Description
This command is used to configure the bridge parameter global settings.
Format
config stp {maxage <value 6-40> | maxhops <value 6-40> | hellotime <value 1-2> |
forwarddelay <value 4-30> | txholdcount <value 1-10> | fbpdu [enable | disable] |
nni_bpdu_addr [dot1d | dot1ad]} (1)
Parameters
maxage - Specifies to determine if a BPDU is valid.
<value 6-40> - Enter to determine if a BPDU is valid. The default value is 20.
maxhops - Specifies to restrict the forwarded times of one BPDU.
<value 6-40> - Enter to restrict the forwarded times of one BPDU. The default value is 20.
hellotime - Specifies the time interval for sending Configuration BPDUs by the Root Bridge. This
parameter is for STP and RSTP version. MSTP version uses per-port hellotime parameter.
<value 1-2> - Enter the time interval for sending Configuration BPDUs by the Root Bridge.
This parameter is for STP and RSTP version. MSTP version uses per-port hellotime
parameter. The default value is 2 seconds.
forwarddelay - Specifies the maximum delay time for one BPDU to be transmitted by a bridge
and received from another bridge.
<value 4-30>- Specifies the maximum delay time for one BPDU to be transmitted by a bridge
and received from another bridge. The default value is 15.
txholdcount - Specifies to restrict the numbers of BPDU transmitted in a time interval (per Hello
Time).
<value 1-10> - Enter to restrict the numbers of BPDU transmitted in a time interval (per Hello
Time).
fbpdu - To decide if the Bridge will flood STP BPDU when STP functionality is disabled.
enable - Specifies to enable FBPDU.
disable - Specifies to disable FBPDU.