Download Print this page

Removing Drive Shaft Housing; Inspection Of Drive Shaft Housing - TOHATSU EverRun MX 18E2 Service Manual

Hide thumbs Also See for EverRun MX 18E2:

Advertisement

Available languages

Available languages

Bracket
1
1
2
2
1
7-28
3
3
2
2

7) Removing Drive Shaft Housing

Use the following steps to remove drive shaft housing.
Remove ground wires 1 from mount bracket 2. Then
1.
remove mount bracket.
2.
Loosen and remove upper rubber mount installation bolts
3.
Loosen right and left rubber mount installation
bolts in several steps alternately and equally.
3.
Remove drive shaft housing.

8) Inspection of Drive Shaft Housing

Check mount rubber 1 and dumper rubber 2 for crack
1.
and deterioration. Replace if necessary.
2.
Check drive shaft housing for corrosion for damage.
3.
Check if drive shaft housing is distorted.
Place the housing on the surface plate and use dial gauge
to measure distortion on the upper face of the housing.
Replace if the difference is over 0.228mm (0.0090in) on
each measuring point.
Use of distorted drive shaft housing may
cause severe wear of drive shaft spline
which may lead to damage on the crank
shaft spline.
CAUTION
2st X18E2 2012
GB

Hide quick links:

Advertisement

loading