Electrical System
/Y
a
c
8-16
b

5) Inspection of C.D.unit

• Measurement of peak volts
1.
Connect Peak Voltage adapter to C.D.unit connectors.
2.
Measure peak volts at shown below.
Replace C.D.unit or check connection of wire harness if
the peak volts out of specified range.
C.D. Unit Peak Volts: (Reference)
Black/Yellow (B/Y) – Black (B)
6) Inspection of Stop Switch
1.
Check conduction of stop switch, and replace if not
conductive.
This test can be made without removing parts.
Switch Position
Remove lock a
Attach lock b
Press switch c
250 V at cranking (500 r/min)
268 V at idling (1000 r/min)
210 V at 1500 r/min
140 V at 3000 r/min
Lead Wire Color
Brown (Br)
Black (B)