TRENDnet User's Guide
Set GVRP time settings
Bridge > GVRP > Time Settings
This section will allow you to define the GARP Join, Leave, and Leave All
Time for each port.
Note: The GARP LeaveTime must be greater than (GARP JoinTimer x2 +
10) and the GARPLeaveAllTime must be greater than (GARP LeaveTime +
10). The acceptable input values are multiples of 10. If you try to enter a
© Copyright 2015 TRENDnet. All Rights Reserved.
value that is not a multiple of 10, the value is rimmed down to the multiple
of 10.
GVRP Time Settings
Port: The port number on the switch.
JoinTime: This parameter is the GARP Join Timer. Its range is
10 - 1073741810 milli-seconds.
LeaveTime: This parameter is the GARP Leave Timer. Its range
is 30 - 2147483630 milli-seconds. This timer must
be set in relation to the GVRP Join Timer according
to the following equation:
GARPLeaveTimer >= (GARPJoinTimer X 2) +
10
LeaveAllTime: This parameter is the GARP Leave Timer. Its range
is 30 - 2147483630 milli-seconds. This timer must
be set in relation to the GVRP Leave Timer
according to the following equation:
GARPLeaveAllTimer > (GARPLeaveTimer +
10)
Action: Modifying settings in the row marked All, will apply
the settings to all ports. Click Apply to apply the
change.
Note: To ensure compatibility between network devices, you need to configure the
same values for the GARP Join Timer, GARP Leave Timer, and GARP Leave All Timer
on all participating GVRP devices in your network.
Go Save Settings to Flash section to save the change on the flash to make
sure the change is permanent.