TRENDnet User's Guide
Cable Diagnostics Test
Tools > Cable Diagnostics
The switch provides a basic cable diagnostic tool in the GUI for verifying
the pairs in copper cabling and estimated distance for troubleshooting
purposes.
Note:
If the cable length displays N/A, it means that the cable length is Not Available. The
may be due to the port being unable to determine the estimated cable length. If
length is displayed as "N/A" it means the cable length is "Not Available". This is due
to the port being unable to obtain cable length/either because its link speed is 10M
or 100M, or the cables used are broken and/or of bad in quality.
The deviation of "Cable Fault Distance" is +/- 2 meters. No cable may be displayed
in the table when the cable is less than 2 meters in length.
© Copyright 2015 TRENDnet. All Rights Reserved.
The test also measures the cable fault and identifies the fault in length according to
the distance from the switch.
Select the port you want to proceed cable test. Then click on Test Now.
The results will be displayed in the Cable Diagnostic Table below.
Cable Diagnostics Table
Port: The port number of the switch.
Test Result: Displays the diagnostic results for each pair in the
cable. One of the following cable status parameters
is displayed:
 OK: There is no problem detected with the cable.
 Open in Cable: There is an open wire within the
cable.
 Short in Cable: Two wires are shorted together
within the cable.
 Cross talk in Cable: There is crosstalk detected
between one pair of wires and another pair
within the cable.
Cable Fault
The distance from the switch port to the cable fault.
Distance:
Cable Length: The length of the cable connected to the switch port.