Use our optional RJ45 D-sub 9 pin console cable (PN72001) for connection.
LED display change button
Used to change the LED display mode settings. For detailed display
information and behavior on each LED display mode, refer to 1.5.
The button operation also allows to configure the LED base mode and loop
detection function (Enable/Disable).
Operation
Press-and-hold
Changes the LED base mode settings. When the LED display button is
for more than
pressed and held for more than 3 seconds, all of the STATUS/ECO, PoE,
3 seconds
GIGA, 100M and FULL LEDs are lit. Release the button to enter the mode
after switching. For detailed behavior on each LED base mode, refer to
1.6.1.
The factory default setting of the LED base mode is Status mode.
Press-and-hold
Changes the loop detection status (Enable/Disable). If the LED display
for more than
change button is pressed and held for more than 10 seconds, the LOOP
10 seconds
HISTORY LED are lit. Release the button to complete the settings. For
detailed behavior on the loop detection function settings, refer to 1.5.3.
The factory default setting of the loop detection function is enable.
Description
16