Screen Description
Admin
Displays whether or not power supply is possible.
Up
Down
Status
Show the power supply status.
Powered
Not
Powered
Overload
Class
Displays the class selected by the Classification function.
Limit
Displays the upper limit of power supply amount. (in units of 200 mW)
Pow.
Displays the amount of power supply. (in units of 100 mW)
Vol.
Displays the voltage.
Cur.
Displays the current.
Available commands are listed below.
S
Set whether the power supply is enabled or disabled.
Press "S." The command prompt changes to "Select port number to be changed>."
Enter the port number to change the setting. Press "0" to change the settings of all
ports at a time. Then, the command prompt changes to "Up or Down PoE port
admin status (U/D)>." Press "U" to enable power supply (Up). Press "D" to disable it
(Down).
L
Set the upper limit of supplied power.
Press "L." The command prompt changes to "Select port number to be changed>."
Enter the port number to change the setting. Press "0" to change the settings of all
ports at a time. Then, the command prompt changes to "Enter the power limit>."
Enter the limit between 3000 and 15400 mW (in units of 200 mW).
Q
Return to the previous menu.
Note:
If power request exceeds the limit of the whole unit, a port with a larger
port number is blocked and stops supplying power.
Displays that power supply is possible.
Displays that power supply is not possible.
Displays that power is supplied.
Displays that power is not supplied.
Displays that power supply is stopped because power request
exceeds the limit.