- Do not touch the photosensitive drum surface.
- Do not expose the photosensitive drum surface to light for a long period of
time.
- Do not touch the rowel of the drum.
8) Mount the drum unit [1], which is provided with the product, to the copier.
Be careful where you hold the drum unit.
9) Secure the drum unit with the one screw [1] with which the dummy drum
has been secured.
F-2-29
F-2-30
F-2-31
10) Push down the developing assembly pressure lever [1] and apply
pressure.
11) Secure the developing assembly pressure lever with the one screw [1].
12) Close the right door.
13) Mount the waste toner box [1].
Point to note after attaching the waste toner receptacle
After attaching the waste toner receptacle, move the waste toner full detec-
tion lever [1] up and down to make sure that the lever is moved smoothly.
Faulty detection may be resulted if the lever is caught in something and is not
moved smoothly.
Chapter 2
F-2-32
F-2-33
F-2-34
F-2-35
2-9