7) The machine must be placed in a well ventilated area. It is important to make sure, however, that the machine is not near the air vent (for suction) of the room.

2.1.2 Selecting the Site of Installation

iR2230 / / iR3530 /
Select the site of installation against the following requirements; if possible, visit the user's before delivery of the machine:
1) There must be a power outlet properly grounded and rated as indicated (+, -10%) for exclusive use by the machine.
2) The environment of the room must be as indicated in the following diagram, and the machine must not be installed near a water faucet, water boiler, humidifier,
or refrigerator:
3) The machine must not be installed near a source of fire or in an area subject to dust or ammonium gas.
If the area is exposed to direct rays of the sun, provide curtains to the window.
4) The room must be well ventilated. (The level of ozone generated by the machine in use will not affect the individuals around it. However, some may find its odor
to be unpleasant, as when working in a poorly ventilated room.)
5) The floor of the machine must be level so that the feet of the machine will remain in contact and the machine will remain level.
6) The machine must be at least 10 cm away from any wall, permitting unobstructed use.
- Without a Finisher Installed
- With a DADF-N1 and Finisher S1 Installed
2-2
107 mm
Humidity (%RH)
80
75
60
40
25
20
10
0
10
(32)
(50)
100 mm min.
100 mm min.
1,983 mm
2,091 mm
F-2-4
15
20
27.5 30
(59)
(68)
(81.5)(86)
Temperature
F-2-5
1,035 mm
F-2-6