E261-0000 Error Code: Because Main Power Supply Pcb Is Faulty; E602-0001 Error Code - Canon iR3570 Service Manual

Canon ir4570; ir3570; ir2870; ir2270 laser multifunction printer/copier
Hide thumbs Also See for iR3570:
Table of Contents

Advertisement

- E2444: Serial communication error (Signal communication error between the machine and SST)

14.2.8.9 E261-0000 Error Code: Because main power supply PCB is faulty

iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / /
[ Inspected by Canon Inc. ]
Description
In a certain inspection case, the error code appeared; however, replacement of the main power supply PCB solved it.
Field Remedy
When the symptom has occurred, re-insert J210 connector of the main power supply PCB. If the symptom still occurs, replace the PCB with a new one.
- E261-0000 Error Code can be displayed when the zero-cross signal is not detected for 500msc or more when the relay is on.
FM2-0260 Main Power Supply PCB Assembly (120V)
FM2-0245 Main Power Supply PCB Assembly (230V)
14.2.8.10 E315-000d Error Code: Because main controller PCB is faulty
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / / / /
[ Inspected by Canon Inc. ]
Description
E315-000d was displayed; however, replacing the main controller PCB corrected it.
- E315-000d can be displayed when there is an error in JBIG decoding.
Field Remedy
When the symptom has occurred, re-insert all the connectors of the main controller PCB. If the symptom still occurs, replace the PCB with a new one.
FM2-4550 Main Controller PCB Assembly (for the iR4570 series)
FM2-4551 Main Controller PCB Assembly (for the iR2230)
14.2.8.11 E520 Error Code: Description of this code
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Manual-related ]
Description
When an error is detected during an operation of the finisher-S1, either of the following error codes is displayed. The cause of these error codes is a problem
in the offset motor (M4), the offset HP sensor (PI6), or the finisher controller PCB.
- E520-0000 can be displayed when PI6 of the offset roller does not go ON even if M4 has been driven for 1000msec.
- E520-0002 can be displayed when PL6 of the offset roller does not go OFF even if M4 has been driven for 1000msec.
14.2.8.12 E602-0001 Error Code: Progress bar stops at one-fifth point because hard disk (HDD) is faulty
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Inspected by Canon Inc. ]
Description
The error code was displayed when the progress bar stopped at about one-fifth point and then the machine kept such a situation for a while. As a solution, the
hard disk (HDD) was replaced with a new one.
- E602-0001 can be displayed when the startup partition (BOOTDEV) cannot be found at startup.
Field Remedy
Turn the control panel switch and the main power switch OFF in sequence, re-connect the HDD, and then turn the main power switch ON. If the symptom
still occurs, replace the HDD with a new one.
WM2-5216 HDD
14.2.8.13 E716-0010 Error Code: Occurs when machine is equipped with 3 Way Unit-A1
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Manual-related ]
Description
E716-0010 can be displayed when an error in the communication with the 3 Way Unit-A1 occurs within 5 sec after detecting the connection with the finisher.
The conceivable causes are the open-circuit of the cable, poor connection of the connectors J741 and J2107F, faulty 3 Way Unit-A1 driver PCB, and faulty
DC controller PCB.
14.2.8.14 E732-0001 Error Code: Because Reader Controller PCB is faulty
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Inspected by Canon Inc. ]
Description
The error code was displayed and the indication "R-CON" was not displayed under the service mode screens [VERSION] and [CLEAR]. Consequently, both
the version check of the ROM on the reader controller PCB and the clear of the RAM were impossible in service mode. However, these symptoms were
corrected by replacing the reader controller PCB with a new one.
- E732-0001: DDI-S communication error
Field Remedy
When the symptom occurs, re-insert all connectors of the reader controller PCB. If the symptom still occurs, replace the PCB with a new one.
FG3-3765 Reader Controller PCB Assembly
14.2.8.15 E732-0001 Error Code: Because DIMMs have poor connection
iR2270 / iR2870 / iR3570 / iR4570 / / / / / iR2230 / / / iR3530 / / / /
[ Case in the field ]
Description
In the field, the error code was displayed. However, it was corrected by re-inserting the DIMMs.
- E732-0001 can be displayed when the DDI-S communication error occurs.
Field Remedy
1. Re-insert the connector J1014 (for DDI communication) on the Main controller PCB.
2. If the symptom still occurs, re-insert the DIMM connected to the main controller PCB (J1004) and the DC controller PCB (J381).
14.2.8.16 E733-0001 Error Code is displayed at FAX reception/transmission; however it is solved by switching OFF/ON
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / / / /
[ Case in the field ]
Chapter 14
0010-6756
0010-7975
0010-4113
0010-4111
0010-4104
0010-4106
0010-4107
0011-2571
14-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2870Ir4570Ir2270

Table of Contents