Display Panel Details - Nikon Eclipse Ni-E Instruction Manual

Upright motorized microscope (focusing nosepiece system)
Hide thumbs Also See for Eclipse Ni-E:
Table of Contents

Advertisement

1

Display Panel Details

The 2-line, 24-character fluorescent display panel on the front of the main body can display the following information:
(1)
Power ON display
When the power is turned on, operation progress is
displayed.
(2)
Motorized device initialization display
The twelve dots displayed to the right of "Initializing"
indicate the connection status or initialization status of
motorized devices.
Motorized device not connected:
Dots displayed
Motorized device connected and initializing:
No dots
Motorized device connected and initialized:
Dots displayed
Each dot represents a motorized device as shown below.
Dot Position
1 (leftmost)
Z-axis (main body's elevating section)
2
DIA field diaphragm
3
Motorized XY stage (X)
4
Motorized XY stage (Y)
Motorized universal condenser
5
(Not used in the focusing nosepiece system)
DIA aperture diaphragm
6
(Not used in the focusing nosepiece system)
(3)
Initialization completion display
Either "Microscope state" or "FUNCTION button function" can be displayed on the display panel.
After initialization completes, the "Microscope state" display pattern 1 is first displayed.
Press a DISPLAY SWITCH button on the front of the main body to select between the "microscope state" display and
the "FUNCTION button's function" display.
"Microscope state" display
Varies depending on connected motorized devices and
has nine patterns.
(See "Microscope state display" on the next page.)
"FUNCTION button's function" display:
As factory default, rotation of a condenser, excitation filter
wheel, and a barrier filter wheel is set as the FUNCTION
button's function, and thus the display will be as shown on
the right.
After a "LOAD MODE" function is set and registered with a
FUNCTION button, the registered mode name will be
displayed. Mode names, MD1 through MD6 are those set
as factory default. Up to four alphanumeric characters can
be used for the name and the name can be changed as
you wish. When the mode name has been changed, new
mode name is displayed.
(See "18.1 Mode Function" for the details on the mode.)
Chapter 3
Individual Operations
Initialization indicator dots and corresponding devices
Motorized Device
_
N i - E
_
V x . x x _ x x x x . x x x x . F 1
D a t a
_
L o a d i n g . . .
Top: Model name, firmware version
Bottom: Program startup progress
_
N i - E
_
V x . x x _ x x x x . x x x x . F 1
I n i t i a l i z i n g . . . . . . . . . . . .
Top: Model name, firmware version
Bottom: Motorized device initialization progress
Dot Position
Motorized Quadrocular Tilting Tube
7
(optical path switching part)
Motorized DSC zooming port for
8
quadrocular tube
9
Motorized ND filter wheel
Motorized epi-fluorescence cube turret 1
10
(1st layer)
Motorized epi-fluorescence cube turret 2
11
(2nd layer)
12
Motorized excitation filter wheel
_ _ _ _
C O N +
C O N -
_ _ _ _
FUNCTION button's function display
(factory default setting)
_ _ _ _
M D 2
_ _ _ _ _
M D 1
_ _ _ _ _
Displaying the mode name when the "LOAD
MODE" function has been set to a FUNCTION
button
42
Motorized Device
_ _ _ _
E X +
_ _ _ _ _
B A +
E X -
_ _ _ _ _
B A -
M D 4
_ _ _ _ _
M D 6
M D 3
_ _ _ _ _
M D 5