1E-7 Engine Lubrication System:
Oil Strainer
Clean the oil strainer if necessary.
Inspect the oil strainer body for damage. If necessary,
replace it with a new one.
Oil Pressure Switch Removal and Installation
Refer to "Electrical Components Location in Section 0A
(Page 0A-10)".
Removal
1) Turn the ignition switch to OFF.
2) Drain engine oil. Refer to "Engine Oil and Filter
Replacement in Section 0B (Page 0B-12)".
3) Disconnect the oil pressure switch lead wire.
4) Remove the oil pressure switch (1).
I718H1150034-01
B817H21506005
I717H1150012-01
1
I717H1150011-01
Installation
1) Install the oil pressure switch, apply BOND to its
thread and tighten it to the specified torque.
: Sealant 99000–31140 (SUZUKI BOND
No.1207B or equivalent)
Tightening torque
Oil pressure switch (a): 14 N·m (1.4 kgf-m, 10.0
lbf-ft)
2) Connect the oil pressure switch lead wire securely.
Refer to "Wiring Harness Routing Diagram (GSF650/
S/A/SAK7) in Section 9A (Page 9A-8)".
Tightening torque
Oil pressure switch lead wire bolt (b): 1.5 N·m (
0.15 kgf-m, 1.1 lbf-ft)
3) Pour engine oil. Refer to "Engine Oil and Filter
Replacement in Section 0B (Page 0B-12)".
Oil Pressure Switch Inspection
Refer to "Oil Pressure Indicator Inspection (GSF650/S/A/
SAK7) in Section 9C (Page 9C-10)".
(a)
I717H1150013-01
(b)
I717H1150014-01
B817H21506006