Alaxala AX6300S Series Instruction Manual page 20

Multilayer switches
Hide thumbs Also See for AX6300S Series:
Table of Contents

Advertisement

Safety Information
Do not turn off the Switch power while software is being updated (when
the
command is being executed).
ppupdate
When the
not turn off the Switch until it is restarted (until the STATUS LED on the
management and switching unit changes from blinking green to constant green).
Failure to do so could result in a Switch failure.
If the ACC LED is lit, do not remove the memory card or turn off the
power.
When the ACC LED on the front panel of the Switch is lit, the memory card is being
accessed. While a memory card is being accessed, do not remove the memory card
or turn off the power. Doing so might damage the memory card. In addition, some
commands require a certain amount of time after being entered to finish accessing
the card. Make sure that the memory card is no longer being accessed before
removing the card or turning off the power.
Handle memory cards carefully.
When inserting a memory card, do not push the card too strongly or flick it with your
finger. When removing a memory card, do not forcibly pull out the card if it is locked.
Doing so might damage the connector of the memory card slot.
Remove the memory card before moving the Switch. If a card is subjected to
excessive force when the Switch is moved, the connector of the memory card slot
might be damaged.
Do not attach any labels to a transceiver.
A label attached to the transceiver indicates that the transceiver is a standard
product from ALAXALA or another manufacturer. However, such labels are attached
where they do not interfere with heat dissipation from the transceiver or the
mechanism that prevents the transceiver from coming loose from the cage.
Attaching a label to a location that interferes with these functions could cause a
malfunction in the transceiver or damage to the Switch.
For power supply facility, avoid a voltage drop caused by inrush current.
When a Switch is turned on, inrush current flows. Consider measures for avoiding a
voltage drop in the power supply facility caused by the inrush current. Voltage drops
affect not only the Switch, but also the devices connected to the same power supply
facility.
Turn off the power before connecting or disconnecting the power supply
cable.
Before connecting or disconnecting a power cable, turn off the power to the device
to be installed or removed.