Read Prior To Operation - Alaxala AX6300S Series Instruction Manual

Multilayer switches
Hide thumbs Also See for AX6300S Series:
Table of Contents

Advertisement

4.2 Read prior to operation

CAUTION
NOTE
NOTE
NOTE
When installing the Switch on a table, position the Switch horizontally
on a worktable strong enough to bear the weight of the Switch. Placing
the Switch in an unstable location, such as on an unsteady or tilting
surface, might cause the Switch to fall, resulting in injury.
Do not obstruct the ventilation slots of the Switch. Doing so causes
heat to accumulate inside the Switch, and could result in fire. Maintain
a space of at least 70 mm around the ventilation slots.
Do not place any objects on the Switch. Doing so might damage the
Switch. Furthermore, the Switch might fall, or become unbalanced,
resulting in injury.
Be sure to wear an antistatic wrist strap.
If you handle the Switch without wearing an antistatic wrist strap, the
Switch might be damaged by static electricity.
Place the Switch where the LEDs can be easily seen.
Route the cables through ducts or cover them for protection. Fiber
optic cables require special handling; lay the cables with a bend radius
of 100 mm or more along the major axis and 50 mm or more along the
minor axis, and protect them with metal covers.
To allow for Switch maintenance, fiber optic cables should be the
necessary length (3 m), and the excess cabling should be bundled
near the Switch. When fiber optic cables and other interface cables
are used together, be sure to avoid applying excessive stress on the
fiber optic cables.
4. Installing a Switch
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax63s-h001-50xAx6304sAx6308s

Table of Contents