Figure 4-62 Turning on the power
(1)
Circuit breaker
NOTE
Set all power switches to ON within five seconds of turning the first
switch on. If you take longer than five seconds, the management and
switching unit detects a power failure, and the failure information is
displayed on the LCD.
If this happens, take action as described in the following table.
Display on the LCD
E8 PS
Msg=00000001
[MD] FAULT 2200
220000aa00bb
The values for
installation status of the power supply unit and the status of the power
supply.
When you set the circuit breaker to OFF and then ON again, wait at least two
NOTE
seconds between the OFF and ON operations.
The Switch is ready.
Set all circuit breakers to ON.
(When the power failure is resolved, the
display on the LCD disappears.)
The Switch is unable to start operation
because the power supply capacity is
insufficient.
Set all circuit breakers to OFF, and then set
them to ON again.
<aa>
and
<bb>
above vary depending on the
4. Installing a Switch
Action
139