the power cable.
CAUTION

4.6.3 Connecting and disconnecting the DC power cable

(1) Connecting the DC power cable
NOTE
Step 1
Remove the terminal board cover.
Figure 4-25 Removing the terminal board cover
(1) Power supply unit
(2) Terminal board cover
(3) Screw (M3)
To disconnect the power cable, set the switch of the power supply unit
to be removed to OFF.
Use the specified DC power cable. Using another cable could result in
fire or electric shock.
Connecting and disconnecting a DC power cable must be performed
by a trained technician or maintenance personnel. The DC power
cable is connected to the terminal board. For this reason, incorrect
handling of the DC power cable could result in fire or electric shock.
Make sure the circuit breaker of the power supply facility is set to OFF
before connecting or disconnecting the DC power cable. Connecting
or disconnecting the cable with the circuit breaker of the power supply
facility set to ON could result in fire or electric shock.
For the specifications defined by ALAXALA for power cables, see
2.4.3 Power supply facility for −48 V DC.