Figure 4-50 Turning on the power
(1) Power switch
NOTE
NOTE
(2) Turning off the power
Step 1
Make sure the software is not being updated (the
Set all power switches to ON within five seconds of turning the first
switch on. If you take longer than five seconds, the management and
switching unit detects a power failure, and the failure information is
displayed on the LCD.
If this happens, take action as described in the following table.
Display on the LCD
E8 PS Msg=00000001
[MD] FAULT 2200
220000aa00bb
The values for
<aa>
and
installation status of the power supply unit and the status of the power
supply.
When you set the power switch to OFF and then ON again, wait at
least two seconds between the OFF and ON operations.
4. Installing a Switch
Action
The Switch is ready.
Set all power switches to ON. (When
the power failure is resolved, the display
on the LCD disappears.)
The Switch is unable to start operation
because the power supply capacity is
insufficient.
Set all power switches to OFF, and then
set them to ON again.
<bb>
above vary depending on the
command is not being
ppupdate