SLIDE MOTOR INSPECTION
1. Disconnect the slide motor connector.
2. Apply battery positive voltage to the slide motor
terminals and inspect the slide motor operation
• If not as specified, replace the slide adjuster.
Motor operation
Forward
Backward
End Of Sie
RECLINER MOTOR INSPECTION
1. Disconnect the recliner motor connector.
2. Apply battery positive voltage to the recliner
motor terminals and inspect the recliner motor
operation.
• If not as specified, replace the slide adjuster.
Motor operation
Forward
Backward
End Of Sie
09-13–10
Connection
B+
GND
A
B
B
A
Connection
B+
GND
B
A
A
B
SEATS
A
M
FORWARD
B
M
FORWARD
id091300800900
B
B
A
BACKWARD
acxuuw00000776
id091300801000
A
B
A
BACKWARD
acxuuw00000905