Dell PowerConnect B-FCXs Configuration Manual page 176

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

5
Managing your IronStack
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Intake Side Temperature Readings:
Boot Prom MAC: 0012.f2db.e500
Syntax: show chassis
Table 26
TABLE 26
This field...
Power Supply 1
Power Supply 2
Fan 1 and Fan 2
Exhaust Side Temperature
Readings
Intake Side Temperature Reading The current temperature reading from the air intake side of the chassis.
Boot Prom MAC
Management MAC
Displaying stack module information
The show module command displays information about the stack unit modules. Output resembles
the following.
PowerConnect(config)# show module
S1:M1 FCX-24G 24-port Management Module
S1:M2 FCX-2XGC 2-port 16G Module (2-CX4)
S1:M3 FCX-1XG 1-port 16G Module (1-XFP)
S3:M1 FCX-48G 48-port Management Module
S3:M2 FCX-1XG 1-port 16G Module (1-XFP)
S3:M3 FCX-1XGC 1-port 16G Module (1-CX4)
S4:M1 FCX-48G 48-port Management Module
S4:M2 FCX-1XGC 1-port 16G Module (1-CX4)
S4:M3 FCX-1XG 1-port 16G Module (1-XFP)
S5:M1 FCX-24G 24-port Management Module
S5:M2 FCX-1XG 1-port 16G Module (1-XFP)
S5:M3 FCX-1XG 1-port 16G Module (1-XFP)
S5:M4 FCX-1XG 1-port 16G Module (1-XFP)
S6:M1 FCX-24G 24-port Management Module
S6:M2 FCX-1XGC 1-port 16G Module (1-CX4)
S6:M3 FCX-1XGC 1-port 16G Module (1-CX4)
S7:M1 FCX-48G 48-port Management Module
S7:M2 FCX-1XGC 1-port 16G Module (1-CX4)
S7:M3 FCX-1XGC 1-port 16G Module (1-CX4)
S8:M1 FCX-48G 48-port Management Module
134
Current temperature : 31.5 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Current temperature : 32.0 deg-C
describes the fields displayed in this output example.
Field definitions for the show chassis command
Describes...
The status of the primary power supply.
The status of the secondary power supply, if present.
The status of the cooling fans
From the air exhaust side of the chassis, the current temperature reading, the
warning level temperature setting, and the shutdown level temperature
setting.
The MAC address of the boot prom
For the Active Controller only, the management MAC address
Module
Status Ports Starting MAC
OK
24
00e0.5201.4000
OK
2
00e0.5201.4018
OK
1
00e0.5201.401a
OK
48
001b.ed5e.c480
OK
1
001b.ed5e.c4b0
OK
1
001b.ed5e.c4b1
OK
48
001b.ed5e.ac00
OK
1
001b.ed5e.ac30
OK
1
001b.ed5e.ac31
OK
24
001b.ed5d.a180
OK
1
001b.ed5d.a198
OK
1
001b.ed5d.a199
OK
1
001b.ed5d.a19a
OK
24
00e0.5200.3000
OK
1
00e0.5200.3018
OK
1
00e0.5200.3019
OK
48
00e0.4444.0000
OK
1
00e0.4444.0030
OK
1
00e0.4444.0031
OK
48
0012.f2eb.d540
PowerConnect B-Series FCX Configuration Guide
53-1002266-01

Advertisement

Table of Contents
loading

Table of Contents