Chapter 25 V Command; Virtual-Domain (Sdv Virtual Device Configuration Submode) - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

virtual-domain (SDV virtual device configuration submode)

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
virtual-domain (SDV virtual device configuration submode)
To configure a persistent virtual domain, use the virtual-domain command in SDV virtual device
configuration submode. To remove a persistent virtual domain, use the no form of the command.
Syntax Description
domain-name
Defaults
No virtual domains are configured by default.
Command Modes
SDV virtual device configuration submode.
Command History
Release
3.1(2)
Usage Guidelines
None.
Examples
The following example shows how to configure a persistent virtual domain.
switch# config terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)# sdv virtual-device name sqa1 vsan 1
switch(config-sdv-virt-dev)# virtual-domain 1
Related Commands
Command
sdv enable
show sdv statistics
Cisco MDS 9000 Family Command Reference
25-2
virtual-domain domain-name
no virtual-domain domain-name
Specifies the persistent virtual domain. The range is 1 to 239 or 0x1 to 0xef.
Modification
This command was introduced.
Description
Enables or disables SAN device virtualization.
Displays SAN device virtualization statistics.