Diagnostics
3
Table 2–5
lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
Table 2–5: MAP 200: Event Codes
Event
Code
400
411
4
POST/IPL diagnostics detected a FRU failure as indicated by an event code 400 with
supplementary event data.
a. At the Hardware View, click Logs and select Event Log. The Event Log
displays.
b. Examine the first two bytes (0 and 1) of event data.
c. Byte 0 is a FRU code that indicates the failed component. Byte 1
is the slot number of the failed FRU (00 for a nonredundant FRU, and 00 or 01 for
redundant FRUs.
Table 2–6
isolation procedures.
Table 2–6: MAP 200: Byte 0 FRU Codes
Byte 0
02
05
06
2–36
Explanation
Power-up diagnostic failure.
Firmware fault.
lists byte 0 FRU codes and associated steps that describe fault
Failed FRU
CTP.
Fan module.
Power supply.
Action
Go to
step
4.
Go to
step
7.
Action
Go to
step
6.
Go to
step
5.
Go to
step
6.
edge switch 2/24 service manual

Advertisement

Table of Contents
loading