HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 196

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Messages
Message
Cannot retrieve port
information.
Cannot retrieve port
statistics.
Cannot run
diagnostics on a port
that is failed.
Cannot run
diagnostics on an
active E_Port.
Cannot run
diagnostics. The port
is not installed.
A–26
Description
Port information
cannot be retrieved
by the Product
Manager application
because the Ethernet
link is down or busy.
Port statistics cannot
be retrieved by the
Product Manager
application because
the Ethernet link is
down or busy.
Port diagnostics
(loopback tests)
cannot be performed
on a port that has
failed any previous
diagnostic (power-on
diagnostic, online
diagnostic, or
loopback test). The
amber LED
associated with the
port illuminates to
indicate the failed
state.
Port diagnostics
cannot be performed
on a configured and
active expansion port
(E_Port).
Port diagnostics
cannot be performed
if the port transceiver
is not installed.
Action
Retry the operation later. If
the condition persists, contact
the next level of support.
Retry the operation later. If
the condition persists, contact
the next level of support.
Reset the port and perform
diagnostics again.
Run diagnostics only on an
inactive E-port.
Install an optical transceiver
or run diagnostics only on a
port with an installed
transceiver.
edge switch 2/24 service manual