Link Incident Log - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

The log contains the following columns:
Date/Time - the date and time the FRU was inserted or removed.
FRU - an acronym representing the FRU type or non-FRU element. The acronyms
are:
— CTP - control processor (CTP) card. The CTP card is not a FRU.
card requires replacement of the switch
— PWR - power supply.
NOTE: Three cooling fans are integrated in each power supply. Cooling fans are not FRUs. A
failed cooling fan requires replacement of the power supply.
Position - a number representing the FRU chassis position. The chassis (slot)
position for a nonredundant CTP card is 0. Chassis slots for redundant power
supplies are 0 and 1.
Action - the action performed (Inserted or Removed).
Part Number - the part number of the inserted or removed FRU.
Serial Number - the serial number of the inserted or removed FRU.

Link Incident Log

The Link Incident Log
incidents and associated port numbers for the switch. The information is useful to
maintenance personnel for isolating port problems and repair verification.
To open the Link Incident Log, select Link Incident Log from the Logs menu on the
navigation control panel.
edge switch 2/24 service manual
(Figure
3–5) displays a history of Fibre Channel link
Repair Information
A failed CTP
3–9

Advertisement

Table of Contents
loading

Table of Contents