Diagnostics
b. Inspect the Beaconing and Operational State fields.
Does the Beaconing field display an On message?
YES
NO
Go to
44
Port beaconing is enabled.
a. Consult the customer and next level of support to determine the reason port
beaconing is enabled.
b. Disable port beaconing:
1. At the View panel, select Operations at the left side of the panel. The
Operations panel opens with the Port Beaconing page displayed.
2. Click the Beaconing State check box for the port. The check mark
disappears from the box and port beaconing is disabled.
3. Return to the View panel (Port Properties tab).
Continue.
45
At the View panel, does the Operational State field display a Segmented message?
NO
YES
Port segmentation is indicated. Go to
event codes are found, go to
Problem Determination on page
46
At the View panel, does the Operational State field display a message indicating a
port problem?
NO
YES
Go to
0700: Fabric, ISL, and Segmented Port Problem Determination on page
Exit MAP.
2–22
step
45.
step 50
to obtain event codes. If no event codes are found, go to
step 50
to obtain event codes. If no
MAP 0700: Fabric, ISL, and Segmented Port
2-79. Exit MAP.
edge switch 2/24 service manual
MAP
2-79.